Turbine Flow MeterB142 Gas QuikSertTUR-UM-00272-EN-02 (June 2014)User ManualRACINE, WI USA R215035ELECTRICAL SAFETYE112860Ci = 0µF Li = 1.65HW/ B1
Operational StartupThe following practices should be observed when installing and starting the meter.MAKE SURE THAT GAS FLOW HAS BEEN SHUT OFF AND PRE
1(6.9)10(69)100(690)1,000(6,900)10(6.9)100(69)1000(694)10,000(6,944)100,000(69,444)Flow RateMCFD(SCFM)Measuring Range vs. System PressureHigh RangePre
1(6.9)10(69)100(690)1,000(6,900)10(6.9)100(69)1000(694)10,000(6,944)100,000(69,444)Flow RateMCFD(SCFM)Measuring Range vs. System PressureMid RangePres
1(6.9)10(69)100(690)1,000(6,900)10(6.9)100(69)1000(694)10,000(6,944)100,000(69,444)Flow RateMCFD(SCFM)Measuring Range vs. System PressureLow RangePres
TROUBLESHOOTING GUIDETrouble Possible Cause RemedyMeter indicates higher than actual rateIncorrect K factor entry Correct K factorDebris on rotor supp
REPLACING TURBINE CARTRIDGESIf a turbine is damaged and it becomes necessary to service the meter, repairs are easily accomplished in the field using
In this equation, the pressure (P) is absolute pressure, that is, the observed gauge pressure plus the atmospheric pressure. The commonly used domesti
K factor Calculation in Standard Cubic FeetIf the running conditions are held constant, the K factor adjustment for converting actual cubic feet to st
SYMBOL EXPLANATIONSREFER TO ACCOMPANYING DOCUMENTS.EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. DO NO
®C USCERTIFICATE OF COMPLIANCEThe products listed below are eligible to bear the CSAMark shown with adjacent indicators ‘C’
Turbine Flow Meter, B142 Gas QuikSertPage ii June 2014
• Turbine Flow Meter, Models BII00 and Bl30 QuikSert, Intrinsically Safe with Entity Parameters Vmax= l0V, Imax = 7mA, Ci = 0µF, Li =
Certicate: 1667574 Master Contract: 215035 Project Date Description2428682 July 19, 2011 Update to include alternative Gas
Turbine Flow Meter, B142 Gas QuikSertINTENTIONAL BLANK PAGEPage 22 June 2014
User ManualINTENTIONAL BLANK PAGEPage 23 June 2014
Turbine Flow Meter, Gas QuikSertwww.badgermeter.comBLANCETT and QuikSert are registered trademarks of Badger Meter, In. Other trademarks appearing in
CONTENTSIntroduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Turbine Flow Meter, B142 Gas QuikSertPage iv June 2014
INTRODUCTIONThe B142 gas turbine flow meter is designed with wear resistant moving parts to provide a long service life with very low maintenance. Sho
DABC1” NPTRACINE, WI USA R215035ELECTRICAL SAFETYE112860Ci = 0µF Li = 1.65HW/ B111113 INSTALLEDVmax = 10V Imax = 3mAS/N XXXXXXXX2220 PSI15.3 MPaMO
SPECIFICATIONSPhysicalInstallation Mounts between 2 inch ANSI raised face flanges. Horizontal or vertical mountingFlow Range/Nominal K Factors See pre
INSTALLATIONBefore installation, the flow meter should be checked internally for foreign material and to be sure that the rotor spins freely. Gas line
Other Factors Aecting PerformanceDo not locate the flow meter or connection cable close to electronic motors, transformers, sparking devices, high vo