Signal ConditionerIntelligent Frequency ConverterSGN-UM-00283-EN-01 (November 2013)User Manual
MAINTENANCE1. Frequent inspection should be made. A schedule for maintenance checks should be determined by the environment and frequency of use. It
User ManualINTENTIONAL BLANK PAGEPage 11 November 2013
www.badgermeter.comB220-954 is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their resp
Signal Conditioner, Intelligent Frequency ConverterPage ii November 2013
CONTENTSINTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Signal Conditioner, Intelligent Frequency ConverterPage iv November 2013
INTRODUCTIONThe Intelligent Frequency Converter is a state-of-the-art digital signal processing device designed to provide exceptional accuracy at a v
CONNECTIONThe 4…20 mA output can drive auxiliary devices (resistive loads) such as displays, recorders and computers, provided that the voltage suppli
Loop Resistance20040060080010001200140010 12 14 16 18 20 22 24Supply Voltage (VDC)Loop Load (Ohm's)Operate in theShaded Region2628 30pFigure 3:
F to IConverter24V DCPowerSupply4…20 mA1000OhmsFigure 5: Power supply calculation example 2Known values are: Total Load Resistance = 1000 Ω Power
CALIBRATIONOTE:N If your Intelligent Frequency Converter was purchased with a B220-954 turbine meter, the two components ship from the factory calibra