Page 1 - Programming Manual

Flow MonitorB2800 Flow Monitor – AdvancedDSY-PM-00286-EN-01 (November 2013)Programming Manual

Page 2 - Page ii November 2013

Flow 4 mA SettingWhen the loop powered option is ordered, the flow rate that corresponds to 4 mA must be set. If the current selection is correct, pre

Page 3 - CONTENTS

LinearizationEnhanced accuracy can be obtained by linearization of the display. The linearization routine will accept a maximum of ten points. Lineari

Page 4 - Page iv November 2013

Automatic Store TotalThe monitor is equipped with a store total feature that works automatically, saving the current total to flash memory. The freque

Page 5 - INTRODUCTION

Pulse Out Freq. In4-20 mAMagnetic Pickup10K30V DC (Max)10…30V DC 1…5V DC 20 mS Pulse250 TypRMAX = (Loop Supply Voltage - 5)0.021 2 3 4 5 6+ -+

Page 6 - SPECIFICATIONS

xxSee NoteNote: Only available when either KGS or LBS are SelectedFigure 6: Advanced programming menuFlow Monitor, B2800 Flow Monitor – Adva

Page 7 - PROGRAMMING

xxFigure 7: 4 - 20 mA programming menuProgramming ManualPage 15 November 2013

Page 8 - Select Rate (Time) Interval

MOUNTING OPTIONS / DIMENSIONS5.75"(146.0 mm)7.00"(177.8 mm)9.25"(235.0 mm)4.00"(101.6 mm)RUN PROGRAMRELAY1 RELAY2Figure

Page 9 - Page 9 November 2013

4.00"(101.6 mm)RUN PROGRAMRELAY1 RELAY25.75"(146.0 mm)7.00"(177.8 mm)12.25"(311.2 mm)Figure 10: Swivel mount Programmi

Page 10 - Page 10 November 2013

ADDITIONAL SCALING PARAMETERSThis information is supplied as a general introduction to the basic concepts used to scale rate displays. The applicabili

Page 11 - Store Total

gpm Average Frequency **UUT Hz Counts/GAL UUT K (Hz × 60)/NK gpm Error (% FS)15.00 769.7 3078.59 14.90 –0.659.06 466.1 3086.75 9.03 –0.385.49 285.2 31

Page 12 - ADDITIONAL INPUT OPTIONS

Flow Monitor, B2800 Flow Monitor – AdvancedPage ii November 2013

Page 13 - Battery Powered

TROUBLESHOOTING GUIDETrouble RemedyNo LCD Display • Check battery voltage. Should be 1.5V DC. Replace if low or dead.No Rate or Total Displayed• Che

Page 14 - See Note

INSTALLATION DRAWING2BACDEFGHABCDEFGH1345610987121112 11 10 9 8 7 6 5 4 3 2 1D59380B2 80001B2 80001Programming ManualPage 21 November 2013

Page 15 - Page 15 November 2013

Flow Monitor, B2800 Flow Monitor – AdvancedINTENTIONAL BLANK PAGEPage 22 November 2013

Page 16 - MOUNTING OPTIONS / DIMENSIONS

Programming ManualINTENTIONAL BLANK PAGEPage 23 November 2013

Page 17 - Figure 10: Swivel mount

www.badgermeter.comBlancett is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their resp

Page 18 - ADDITIONAL SCALING PARAMETERS

CONTENTSINTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 19 - DEFAULT K FACTOR VALUES

MOUNTING OPTIONS / DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16ADDIT

Page 20 - REPLACEMENT PARTS

INTRODUCTIONThe B2800 Flow monitor is a state-of-the-art digital signal processing flow monitor, designed to provide the user with exceptional flexibi

Page 21 - INSTALLATION DRAWING

SPECIFICATIONSPower Supply OptionsBattery Powered One D size, 1.5V alkaline battery.Loop Powered Optional 4-20 mA loop power.Power ConsumptionBattery

Page 22 - INTENTIONAL BLANK PAGE

OPERATING THE MONITORThe monitor has two modes of operation referred to as the RUN mode and the PROGRAM mode. Both the RUN mode and the PROGRAM mode d

Page 23

ProgrammingKeysModeIndicatorUnits DisplayAnd Programming ChoicesRate / Total DisplayAnd Programming ChoicesRUN PROGRAMRELAY1 RELAY2Figure 2

Page 24

Select Units of MeasureIf a flow amount is desirable, the units for the total must first be chosen. The monitor allows the choice of many common total