RTS-UM-00380-EN-08 (April 2014)User ManualRecordall® Turbo Series MetersModels 160 (1-1/2"), 200 (2"), 450 (3"), 1000 (4"), 2000 (
Calibration Check and AdjustmentThe accuracy of the Recordall Turbo Series meters is tested at the factory before shipment. However, after a long peri
CalibrationThe meter's calibration ring is preset and sealed at the factory. In normal service, it should not have to be reset. If a retest is re
SERVICING PARTS AND ASSEMBLIESWhen the performance of a Turbo meter indicates a need for servicing, refer to the following instructions pertaining to
Removing the Measuring ElementOTE:N A cage seal is installed in the 1-1/2" to 6" Recordall® Turbo Series so that the entire water volume flo
Removing the rear nose coneTo remove the rear nose cone, you must remove the transmission shaft. See Figure 3, Figure 4, Figure 5 and Figure 6.1. Rem
CALIBRATION LINKAGEARROW TIPCAGE INSERTNOSE CONETOP SIDESMALL HOLE WITHCHAMFER UPLARGE HOLE WITHCHAMFER DOWNINTO CAGE THIS ENDCALIBRATION RINGPIN1-1/2
ROTORROTOR WORMBEARINGS (2)NOSE CONE ASSEMBLY (2)BEARING PINFigure 6: Rotor and nose cone assembly (1-1/2", 2", 3", 4" and 6"
Reinstalling the Turbo Meter Head Assembly• Use a new O-ring after each teardown and reassembly. • To provide a tight seal, make sure the surfaces o
SPECIFICATIONS1-1/2" to 12" MetersTurbo Series Model1601-1/2" (40 mm)2002" (50 mm)4503" (80 mm)10004" (100 mm)20006"
16" and 20" MetersTurbo Series Model660016" (400 mm)1000020" (500 mm)Meter Flanges Raised-Face Round Raised-Face RoundTypical Oper
Recordall® Turbo Series MetersPage ii April 2014
www.badgermeter.comMAKING WATER VISIBLE, ORION, RECORDALL and RTR are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this d
CONTENTSSCOPE OF THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recordall® Turbo Series MetersPage iv April 2014
SCOPE OF THIS MANUALThis manual contains installation, operation and maintenance procedures for the Badger Meter® Recordall® Turbo Series meters with
Safety InformationThe installation of the Recordall Turbo Series meter must comply with all applicable federal, state, and local rules, regulations, a
INSTALLATIONProcedures for installing Recordall Turbo Series meters are essentially the same for all meter sizes. Any special instructions required fo
◊ Do not install check valves or pressure reducing devices upstream of the meter.◊ Valves immediately upstream of the meter should only be fully-ope
MAINTENANCEThis section is limited to information pertaining to the general maintenance of Badger Meter Recordall Turbo Series meters. An exploded vie